No products in the cart.
Mercury ELITE 2200U SMART 3000VA 1200W
Input | |
Capacity | 2000VA/1200W |
Voltage Range (220V) | 140~300VAC |
Frequency | 50/60Hz (Auto-sensing) |
Phase | Single-phase |
Socket | With Fuse |
Cold Start | Press the ON/OFF switch (0%~100% load) |
Output | |
Rating Capacity | 2000VA |
Rating Power | 1200W |
Waveform | Waveform Battery mode (Simulated Sinewave) AC mode (Sinewave) |
Power Factor | 0.6 |
Rating Voltage | 220VAC |
AC Voltage Regulation | ±10% (Battery mode) |
Rear Output Socket | 4 x Universal (Battery backup) |
Output Frequency | |
Rating Frequency | 50/60Hz±1Hz |
Line Mode | Synchronize with the utility |
Environment | |
Temperature | 0˚C~40˚C |
Humidity | 0%~90%RH (Non-condensing) |
Noise Level | Less than 45dB |
Indicators | |
AC Mode | Greenlighting |
Battery Mode | Yellow flashing |
Fault | Red lighting |
Physical | |
Dimensions (WxDxH) (mm) | 390 x 125 x 225 |
Net Weight (kg) | 13.4±0.3 |
Transfer Time | Typical 2~6ms (Max 10ms) |
Communication Interface | USB/RJ11 (Optional) |
Battery & Runtime | |
Rating Voltage | 12V/9AH x 2 |
Recharge Time | 6-8 hrs recover to 90% capacity |
Change Current | About 1A at Normal mode |
Short Circuit Protection | |
Line Mode | Fuse & firmware protection |
Battery Mode | Firmware protection |
Overload Protection | |
Line Mode | Load<110%±5% go to fault mode after 5 mins |
Load<120%±5% go to fault mode immediately | |
Battery Mode | Load<110%±5% shut down after 5 secs |
Load<120%±5% shut down immediately | |
Protection | |
Full Protection | Overload, discharge & overcharge protection |
Alarm | |
Battery Mode | Sounding every 10 secs |
Low Battery | Sounding every sec |
Overload | Sounding every 0.5 sec |
Fault | Continuously sounding |
Management | |
Compatible with OS | Supports Windows® 2000/2003/XP/Vista/2008/7/8.1/10 |
UPS Mode | OFFLINE UPS |
---|
المراجعات